The TEnt.T trace covers 20 to 25.109 °C, a temperature span of 5.109 K. The first recorded maximum occurs at 15,602,976 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named YorkCalc. The source file places it under Fluid, Heat Exchangers, Cooling Towers. We used the 101 stored values for TEnt.T over the interval 15,552,000 to 15,638,400 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name TSetLea (Constant), conFan (Lim PID). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel tow.TWetBul covers 284.806 to 293.292 K. At 15,563,232 s, the primary value is 296.047 and the companion is 284.818. Their signed difference is 11.228 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Cooling tower using the york performance correlation. The simulated TEnt.T channel runs from 293.15 to 298.259 K over 86,400 seconds.
Cooling tower using the york performance correlation. The simulated TEnt.T channel runs from 293.15 to 298.259 K over 86,400 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 15,552,864 to 15,553,728 seconds. Subtracting 293.15 from 295.231 gives 2.081 K. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

TEnt.T (K)

tow.TWetBul (K)

1.5552e+07

293.15

285.3654

1.555286e+07

293.15

285.3654

1.555373e+07

295.2309

285.3654

1.556928e+07

294.4579

285.2372

1.558656e+07

295.7035

290.3576

1.560298e+07

298.2591

292.9445

1.560384e+07

298.1733

292.5951

1.562112e+07

295.512

289.5267

1.56384e+07

295.8429

285.4686

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.

Cover photograph by Jakub Zerdzicki, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.