The recorded loa.m_flow channel spans 0 to 0.3983 kg/s in this reference run. It starts at 0 and ends at 0.2656. The first recorded maximum occurs at 64,800 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named Indirect. The source file places it under DHC, ETS, Cooling. We used the 101 stored values for loa.m_flow over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name cooETS (Indirect), souDis (Boundary p T), sinDis (Boundary p T), TSetCHWS (Constant). The source declares QCoo_flow_nominal = -19000, dT_nominal = 16-7. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel cooETS.hex.m1_flow starts at 1.35e-06, ends at 0.2579 and has a recorded range of 1.35e-06 to 0.3942 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Cooling indirect. The simulated loa.m_flow channel runs from 0 to 0.3983 kg/s over 86,400 seconds.
Cooling indirect. The simulated loa.m_flow channel runs from 0 to 0.3983 kg/s over 86,400 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed rate over 86,400 seconds gives a net 19,136 kg. This estimate averages neighbouring stored rates and multiplies by their time separation. Reverse flow reduces the net total. If a process requires gross throughput, calculate forward and reverse transfers separately at the appropriate boundary.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

loa.m_flow (kg/s)

cooETS.hex.m1_flow (source units)

0

0

1.345514e-06

864

0.2634375

0.0130635

17280

0.2230721

0.1936529

34560

0.08497993

0.07748786

51840

0.1912041

0.1814724

64800

0.3983071

0.3941979

69120

0.3717869

0.3672735

86400

0.2655621

0.2578819

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.

Cover photograph by Mikhail Nilov, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.