The recorded cooETS.Q_flow channel spans -150,024 to 0 W in this reference run. It starts at 0 and ends at -99,997. The first recorded maximum occurs at 0 seconds and the first minimum at 64,800 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named Direct. The source file places it under DHC, ETS, Cooling. We used the 101 stored values for cooETS.Q_flow over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name cooETS (Direct), TSetDisRet_min (Constant), sinDis (Boundary p T), souDis (Boundary p T). The source declares Q_flow_nominal = -18000. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel cooETS.Q starts at 0, ends at -7,058,478,592 and has a recorded range of -7,058,478,592 to 0 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Reproduce the calculation
Integrating the signed cooETS.Q_flow samples by the trapezoidal rule gives -1,964 kWh over 86,400 seconds. For each pair, average the two powers in watts and multiply by the interval in seconds. Sum the watt-seconds and divide by 3,600,000. This value refers to the selected simulation connector and should be assigned to a physical load only after confirming the boundary and sign.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | cooETS.Q_flow (W) | cooETS.Q (source units) |
|---|---|---|
0 | 0 | 0 |
17280 | -84019.59 | -1.412141e+09 |
21600 | -80024.27 | -1.766479e+09 |
22464 | -48662.96 | -1.809174e+09 |
34560 | -32000.11 | -2.297837e+09 |
51840 | -71992.38 | -2.919761e+09 |
64800 | -150024.3 | -4.358479e+09 |
69120 | -139999.4 | -4.984879e+09 |
86400 | -99997.32 | -7.058479e+09 |
What to check on site
Mark the measurement points on a hydraulic schematic and identify whether the controller holds flow or differential pressure. Record pump command and delivered duty together. A site comparison needs the same branch state, including bypasses and closed valves.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.