The recorded hex.port_a2.m_flow channel spans -0.14 to 0.14 kg/s in this reference run. It starts at 0 and ends at 0. The first recorded maximum occurs at 36 seconds and the first minimum at 2,160 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named WetCoilCounterFlowMassFlow. The source file places it under Fluid, Heat Exchangers. We used the 101 stored values for hex.port_a2.m_flow over the interval 0 to 3,600 seconds. This is a simulated test with specified inputs and boundaries.
The reference file contains 4 recorded variables. Alongside the primary output there are hex.Q2_flow, hex.QLat2_flow, hex.port_a2.m_flow, hex.port_b2.m_flow. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.
Compare the recorded channels
The companion channel hex.port_b2.m_flow covers -0.14 to 0.14 kg/s. At 36 s, the primary value is 0.14 and the companion is -0.14. Their signed difference is 0.28 kg/s, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reproduce the calculation
Integrating the signed rate over 3,600 seconds gives a net 224.282 kg. This estimate averages neighbouring stored rates and multiplies by their time separation. Reverse flow reduces the net total. If a process requires gross throughput, calculate forward and reverse transfers separately at the appropriate boundary.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | hex.port_a2.m_flow (kg/s) | hex.port_b2.m_flow (kg/s) |
|---|---|---|
0 | 0 | -0.14 |
36 | 0.14 | -0.14 |
720 | 0.14 | -0.14 |
1440 | 0.14 | -0.14 |
2160 | -0.1399754 | 0.14 |
2880 | 0 | 0 |
3600 | 0 | 0 |
What to check on site
Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.