The recorded conRelHum.relHumOut channel spans 0.44 to 1 source units in this reference run. It starts at 0.73 and ends at 0.44. The first recorded maximum occurs at 8,121,600 seconds and the first minimum at 8,640,000 seconds.

The system being tested

The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named ConvertRelativeHumidity. The source file places it under Boundary Conditions, Weather Data. We used the 101 stored values for conRelHum.relHumOut over the interval 0 to 8,640,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name conRelHum (Convert Relative Humidity), modTim (Model Time), conTim (Convert Time), datRea (Combi Table1 Ds). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The primary channel spends 63.4% of its saved checkpoints at or above 0.72 source units, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 0.7472 source units. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Converting relative humidity and checking its validity. The simulated conRelHum.relHumOut channel runs from 0.44 to 1 source units over 8,640,000 seconds.
Converting relative humidity and checking its validity. The simulated conRelHum.relHumOut channel runs from 0.44 to 1 source units over 8,640,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 8,553,600 to 8,640,000 seconds. Subtracting 0.91 from 0.44 gives -0.47 source units. Its location brackets the change within one saved interval of 86,400 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

conRelHum.relHumOut (source units)

0

0.73

1728000

0.85

3456000

0.75

5184000

0.76

6912000

0.52

8121600

1

8553600

0.91

8640000

0.44

What to check on site

Check the time reference, location and receiving plane for each environmental input. Two measured series can differ because one records horizontal exposure and the other a tilted surface. A comparison needs the same averaging interval and geometric definition.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.