The recorded extCon.port_a.Q_flow channel spans 551.646 to 2,718 W in this reference run. It starts at 2,666 and ends at 551.646. The first recorded maximum occurs at 100,000 seconds and the first minimum at 1,000,000 seconds.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named Convection. The source file places it under Buildings, Components, Convective Heat Transfer. We used the 101 stored values for extCon.port_a.Q_flow over the interval 0 to 1,000,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name monLayAirWal (Mono Layer Air), intConVer (Interior Convection), extCon (Exterior Convection), preTem (Prescribed Temperature). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel extConLin.port_a.Q_flow covers 983.932 to 4,643 W. At 100,000 s, the primary value is 2,718 and the companion is 4,643. Their signed difference is -1,924 W, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Convection model tests. The simulated extCon.port_a.Q_flow channel runs from 551.646 to 2,718 W over 1,000,000 seconds.
Convection model tests. The simulated extCon.port_a.Q_flow channel runs from 551.646 to 2,718 W over 1,000,000 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed extCon.port_a.Q_flow samples by the trapezoidal rule gives 506.376 kWh over 1,000,000 seconds. For each pair, average the two powers in watts and multiply by the interval in seconds. Sum the watt-seconds and divide by 3,600,000. This value refers to the selected simulation connector and should be assigned to a physical load only after confirming the boundary and sign.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

extCon.port_a.Q_flow (W)

extConLin.port_a.Q_flow (W)

0

2665.967

4556.7

100000

2718.437

4642.669

200000

2573.693

4405.254

400000

1959.108

3387.533

600000

1239.037

2172.504

800000

1452.521

2535.567

900000

1049.712

1848.3

910000

723.2243

1283.75

1000000

551.6455

983.9325

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.