The conAHU.TOut trace covers 13 to 23 °C, a temperature span of 10 K. The first recorded maximum occurs at 900 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named Controller_UnspecifiedClimate. The source file places it under Controls, OBC, ASHRAE, G36, AH Us, Multi Zone, variable air volume. We used the 101 stored values for conAHU.TOut over the interval 0 to 3,600 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name conAHU (Controller), TSup (Ramp), VOut_flow (Ramp), TMixMea (Ramp). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel conAHU.TAirSup starts at 287.15, ends at 291.15 and has a recorded range of 287.15 to 291.15 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Controller model for generating warning when the climate zone is not specified. The simulated conAHU.TOut channel runs from 286.15 to 296.15 K over 3,600 seconds.
Controller model for generating warning when the climate zone is not specified. The simulated conAHU.TOut channel runs from 286.15 to 296.15 K over 3,600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 36 seconds. Subtracting 291.15 from 291.464 gives 0.314 K. Its location brackets the change within one saved interval of 36 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

conAHU.TOut (K)

conAHU.TAirSup (source units)

0

291.15

287.15

36

291.464

287.19

720

295.9053

287.95

900

296.15

288.15

1440

294.0889

288.75

2160

288.2111

289.55

2700

286.15

290.15

2880

286.3947

290.35

3600

291.15

291.15

What to check on site

Separate a calculated setpoint from the damper or fan command and from the measured service delivered. Trend the active operating mode, request, actual flow and zone condition on one clock. A sequence can change state correctly while the terminal fails to reach duty.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.