The con.TSup trace covers 6.014 to 19.986 °C, a temperature span of 13.972 K. The first recorded maximum occurs at 20,736 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named ControllerChillerDXHeatingEconomizer. The source file places it under Air, Systems, Single Zone, variable air volume. We used the 101 stored values for con.TSup over the interval 0 to 172,800 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name mixAirTem (Sine), retAirTem (Sine), outAirTem (Sine), con (Controller Chiller direct expansion Heating Economizer). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel con.yFan starts at 0, ends at 0 and has a recorded range of 0 to 1 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Controller chiller direct expansion heating economiser. The simulated con.TSup channel runs from 279.164 to 293.136 K over 172,800 seconds.
Controller chiller direct expansion heating economiser. The simulated con.TSup channel runs from 279.164 to 293.136 K over 172,800 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 1,728 seconds. Subtracting 286.15 from 287.027 gives 0.8773 K. Its location brackets the change within one saved interval of 1,728 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

con.TSup (K)

con.yFan (source units)

0

286.15

0

1728

287.0273

0

20736

293.1362

0.5635514

34560

290.2645

1

63936

279.1638

0.1

69120

279.4926

0.1

103680

292.8074

0.210518

138240

282.0355

0.1

172800

286.15

0

What to check on site

Read the evaporator, condenser and electrical channels at the same duty. The water or air temperatures entering the equipment constrain capacity and efficiency. A compressor command does not specify how much heat actually crosses the useful-load boundary.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.