The pSat trace ranges from 101,418 Pa to 1,000,008.4 Pa across 101 saved checkpoints. It begins at 101,418 Pa and finishes at 1,000,008.4 Pa after 1 s of test time. The source identifies the channel scale as Pa. Its first saved maximum occurs at 1 s.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named SteamSaturationConsistencyCheck. The source file places it under Media. We used the 101 stored values for pSat over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name sat (Thermodynamic State), pSat (Pressure), TSat0 (Temperature), TSat (Temperature). The source declares TMin = 273.15 + 100, TMax = 273.15 + 179.886, tol = 1E-8. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 1 s, pSat reads 1,000,008.4 Pa and TSat0 reads 453.036 K. Across the run, the second channel ranges from 373.15 K to 453.036 K. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0.99 to 1 seconds. Subtracting 981,758 from 1,000,008 gives 18,251 source units. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

pSat (Pa)

TSat0 (K)

0

101418

373.15

0.2

174638.7

389.1272

0.4

286436.1

405.1044

0.6

450286.7

421.0816

0.8

682067.2

437.0588

0.99

981757.5

452.2372

1

1000008

453.036

What to check on site

Compare fuel or electrical input with useful heat at a declared delivery boundary. Include the warm-up interval and any period on standby. Separate a temperature setpoint from the measured outlet and keep auxiliary energy in a stated part of the balance.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Units in the source model

The component declarations identify the scale of the exported variables. In this run, pSat uses Pa and TSat0 uses K. Keep the exact channel name and unit together when exporting data to a historian. Read the component definition.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.