The recorded pumConPipe_R.m_flow_actual channel spans 0 to 0.5 source units in this reference run. It starts at 0 and ends at 0.5. The first recorded maximum occurs at 1,836 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named Connection1PipeExample. The source file places it under DHC, Networks, Connections. We used the 101 stored values for pumConPipe_R.m_flow_actual over the interval 0 to 3,600 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name pumDisPipe_R (Pump m flow), pumConPipe_R (Pump m flow), pumDisPlugFlow (Pump m flow), pumConPlugFlow (Pump m flow). The source declares mDis_flow_nominal = 1, mCon_flow_nominal = 0.5, lDis = 100. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The primary channel spends 49.5% of its saved checkpoints at or above 0.25 source units, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 0.2475 source units. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Connections connection1 pipe. The simulated pumConPipe_R.m_flow_actual channel runs from 0 to 0.5 source units over 3,600 seconds.
Connections connection1 pipe. The simulated pumConPipe_R.m_flow_actual channel runs from 0 to 0.5 source units over 3,600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 1,800 to 1,836 seconds. Subtracting 0 from 0.5 gives 0.5 source units. Its location brackets the change within one saved interval of 36 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

pumConPipe_R.m_flow_actual (source units)

0

0

720

0

1440

0

1800

0

1836

0.5

2160

0.5

2880

0.5

3600

0.5

What to check on site

Distinguish the component characteristic from the installed system response. Record the pressure or temperature on both sides as applicable, the direction of flow and the actuator command. Compare a change at constant demand with one caused by a different load.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.