The con.port_a.T trace covers 20 to 29.12 °C, a temperature span of 9.12 K. The first recorded maximum occurs at 86,400 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named ConductorMultiLayer2. The source file places it under Heat Transfer. We used the 101 stored values for con.port_a.T over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 7 recorded variables. Alongside the primary output there are con.T[2], con.T[1], con.port_b.T, con.T[5], con.T[3]. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The companion channel con.T[2] covers 293.15 to 297.872 K. At 44,928 s, the primary value is 301.029 and the companion is 294.863. Their signed difference is 6.167 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Conductor multi layer2. The simulated con.port_a.T channel runs from 293.15 to 302.27 K over 86,400 seconds.
Conductor multi layer2. The simulated con.port_a.T channel runs from 293.15 to 302.27 K over 86,400 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 43,200 to 44,064 seconds. Subtracting 293.15 from 299.244 gives 6.094 K. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

con.port_a.T (K)

con.T[2] (K)

0

293.15

293.15

17280

293.15

293.15

34560

293.15

293.15

43200

293.15

293.15

44064

299.2444

293.8322

51840

302.217

297.6178

69120

302.2645

297.8388

86400

302.2703

297.8724

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.