The T trace covers -1.411 to 58.589 °C, a temperature span of 60 K. The first recorded maximum occurs at 1 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named Temperature_u. The source file places it under Heat Transfer, Conduction. We used the 101 stored values for T over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name u (Specific Internal Energy), T (Temperature), TMonotone (Temperature), TExa (Temperature). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel TMonotone starts at 271.739, ends at 331.739 and has a recorded range of 271.739 to 331.739 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0.99 to 1 seconds. Subtracting 320.27 from 331.739 gives 11.47 K. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | T (K) | TMonotone (source units) |
|---|---|---|
0 | 271.7391 | 271.7391 |
0.2 | 305.6862 | 304.8716 |
0.4 | 307.5908 | 307.1348 |
0.6 | 309.4953 | 309.9043 |
0.8 | 311.3998 | 312.2247 |
0.99 | 320.2696 | 320.2696 |
1 | 331.7391 | 331.7391 |
What to check on site
Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.