The recorded zoneBlock.TSensor channel spans 292.43 to 293.222 source units in this reference run. It starts at 293.15 and ends at 292.43. The first recorded maximum occurs at 360 seconds and the first minimum at 2,000 seconds.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named NumberOccupants. The source file places it under Buildings, Components. We used the 101 stored values for zoneBlock.TSensor over the interval 0 to 2,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name zoneFixed (Simple Zone), zoneInput (Simple Zone), zoneBlock (Simple Zone), zoneAreaWeightedInput (Simple Zone). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel zoneFixed.TSensor covers 292.259 to 293.15 source units. At 1,460 s, the primary value is 292.787 and the companion is 292.398. Their signed difference is 0.3897 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Components number occupants. The simulated zoneBlock.TSensor channel runs from 292.43 to 293.222 source units over 2,000 seconds.
Components number occupants. The simulated zoneBlock.TSensor channel runs from 292.43 to 293.222 source units over 2,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 700 to 720 seconds. Subtracting 292.99 from 292.966 gives -0.02414 source units. Its location brackets the change within one saved interval of 20 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

zoneBlock.TSensor (source units)

zoneFixed.TSensor (source units)

0

293.15

293.15

360

293.2221

292.9105

400

293.2203

292.8853

700

292.9898

292.7115

720

292.9657

292.701

800

292.873

292.6601

1200

292.7602

292.4863

1600

292.701

292.3565

2000

292.4295

292.2589

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.

Cover photograph by Mikhail Nilov, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.