The recorded zoneOcc.TSensor channel spans 292.004 to 293.15 source units in this reference run. It starts at 293.15 and ends at 292.004. The first recorded maximum occurs at 0 seconds and the first minimum at 5,000 seconds.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named LightingControl. The source file places it under Buildings, Components. We used the 101 stored values for zoneOcc.TSensor over the interval 0 to 5,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name zoneFixed (Simple Zone), zoneInput (Simple Zone), zoneBlock (Simple Zone), zoneOcc (Simple Zone). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel zoneFixed.TSensor covers 291.84 to 293.15 source units. At 5,000 s, the primary value is 292.004 and the companion is 291.84. Their signed difference is 0.1637 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Components lighting control. The simulated zoneOcc.TSensor channel runs from 292.004 to 293.15 source units over 5,000 seconds.
Components lighting control. The simulated zoneOcc.TSensor channel runs from 292.004 to 293.15 source units over 5,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 50 to 100 seconds. Subtracting 293.105 from 293.06 gives -0.04526 source units. Its location brackets the change within one saved interval of 50 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

zoneOcc.TSensor (source units)

zoneFixed.TSensor (source units)

0

293.15

293.15

50

293.1048

293.117

100

293.0596

293.0831

1000

292.4497

292.5602

2000

292.3323

292.2438

3000

292.1977

292.0701

4000

292.093

291.9452

5000

292.0037

291.84

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.