The recorded CooRea.Q_flow channel spans -55,528 to -19,365 W in this reference run. It starts at -19,365 and ends at -55,528. The first recorded maximum occurs at 0 seconds and the first minimum at 12,672 seconds.
The system being tested
The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named Cooler. The source file places it under Airflow, Air Handling Unit, Modular Air Handling Unit, Components. We used the 101 stored values for CooRea.Q_flow over the interval 0 to 14,400 seconds. This is a simulated test with specified inputs and boundaries.
The reference file contains 3 recorded variables. Alongside the primary output there are CooRea.Q_flow, preOut.Q_flow, resPow.y. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.
Compare the recorded channels
The companion channel preOut.Q_flow covers -55,720 to -5,073 W. At 0 s, the primary value is -19,365 and the companion is -5,073. Their signed difference is -14,292 W, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reproduce the calculation
Integrating the signed CooRea.Q_flow samples by the trapezoidal rule gives -132.367 kWh over 14,400 seconds. For each pair, average the two powers in watts and multiply by the interval in seconds. Sum the watt-seconds and divide by 3,600,000. This value refers to the selected simulation connector and should be assigned to a physical load only after confirming the boundary and sign.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | CooRea.Q_flow (W) | preOut.Q_flow (W) |
|---|---|---|
0 | -19364.82 | -5072.7 |
2880 | -19364.82 | -19408.33 |
5760 | -29509.38 | -29553.73 |
8640 | -35520.26 | -35627.9 |
11520 | -44422.23 | -44575.73 |
12240 | -51825.94 | -52005.02 |
12384 | -53306.68 | -53490.87 |
12672 | -55527.79 | -55719.66 |
14400 | -55527.79 | -55719.66 |
What to check on site
Identify the connected zones, pressure references and flow direction. Changing a door, leakage path or boundary condition can redistribute the same total flow between branches. A differential pressure alone cannot establish the air quantity reaching a zone.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.