The winCei.shaType.HDirTil trace ranges from 0 to 213.211 across 101 saved checkpoints. It begins at 0 and finishes at 0.084788 after 1,000,000 s of test time. The reference export does not state a verified engineering unit for this value. Use its native scale when comparing another run of the same model.
The system being tested
The largest change in winCei.shaType.HDirTil between saved samples lies between simulation times 2,450,000 s and 2,460,000 s. The channel moves from 0.67871 to 188.937 across that interval. A finer export is needed to resolve what happens between those observations.
The component declarations name winWal (Window), winFlo (Window), winCei (Window). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The two named channels have separate paths in the model. winCei.shaType.HDirTil begins at −0 and ends at 0.084788. winWal.shaType.HDirTil begins at −0 and ends at 1.5468. The reference export supplies numerical samples but does not attach a physical unit to these fields. Use the linked model declarations to establish the quantity and units of each channel before calculating a difference or assigning it a physical meaning.
Reproduce the calculation
The largest absolute change between consecutive stored points appears from 2,450,000 to 2,460,000 seconds. Subtracting 0.6787 from 188.937 gives 188.259 source units. Its location brackets the change within one saved interval of 10,000 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | winCei.shaType.HDirTil (source units) | winWal.shaType.HDirTil (source units) |
|---|---|---|
2000000 | 0 | 0 |
2200000 | 2.161661 | 6.648005 |
2400000 | 0 | 0 |
2450000 | 0.6787093 | 82.97973 |
2460000 | 188.9374 | 539.131 |
2600000 | 0 | 0 |
2640000 | 213.2113 | 545.27 |
2800000 | 1.244948 | 4.802828 |
3000000 | 0.0847881 | 1.546757 |
What to check on site
Check the time reference, location and receiving plane for each environmental input. Two measured series can differ because one records horizontal exposure and the other a tilted surface. A comparison needs the same averaging interval and geometric definition.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Checking the two recorded channels
At 2,460,000 s, winCei.shaType.HDirTil reads 188.937 and winWal.shaType.HDirTil reads 539.131. Across the run, the second channel ranges from 0 to 545.27. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.