The recorded zone.TSensor temperature spans 7.1228 °C to 20 °C in this simulation. That is a change of 12.877 K. The first saved maximum occurs at 0 s. The source trace and download retain absolute temperatures in kelvin.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named RectangularZone. The source file places it under Buildings, Components. We used the 101 stored values for zone.TSensor over the interval 0 to 604,800 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name zoneIntWal (Case900 Template), zone (Case900 Template). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 114,912 s, zone.TSensor is 284.739 K and zoneIntWal.TSensor is 288.514 K. Subtracting the second value from the first gives -3.7753 K. This is their largest recorded absolute separation. A difference between an inlet and an outlet, or between a command and a response, need not be a measurement error.

Compares a zone with internal wall and without internal wall. The simulated zone.TSensor channel runs from 280.273 to 293.15 source units over 604,800 seconds.
Compares a zone with internal wall and without internal wall. The simulated zone.TSensor channel runs from 280.273 to 293.15 source units over 604,800 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 120,960 to 127,008 seconds. Subtracting 285.123 from 287.418 gives 2.294 source units. Its location brackets the change within one saved interval of 6,048 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

zone.TSensor (K)

zoneIntWal.TSensor (K)

0

293.15

293.15

120960

285.1235

288.7228

127008

287.4178

289.8277

241920

286.7334

288.8036

362880

282.3877

285.9425

483840

283.0495

285.2791

550368

280.2728

283.4556

604800

280.6894

283.247

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Units in the source model

The component declarations identify the scale of the exported variables. In this run, zone.TSensor uses K and zoneIntWal.TSensor uses K. Keep the exact channel name and unit together when exporting data to a historian. Read the component definition.

Data and source model