The recorded case900WithFloor.building.floor.propsBus_a.surfRad.Q_flow channel spans -932.466 to 3,277 W in this reference run. It starts at 33.566 and ends at -163.357. The first recorded maximum occurs at 1,770,000 seconds and the first minimum at 1,620,000 seconds.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named BeamRadiationOnFloor. The source file places it under Buildings, Components. We used the 101 stored values for case900WithFloor.building.floor.propsBus_a.surfRad.Q_flow over the interval 0 to 3,000,000 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 4 recorded variables. Alongside the primary output there are case900WithFloor.building.floor.propsBus_a.surfRad.Q_flow, case900WithoutFloor.building.floor.propsBus_a.surfRad.Q_flow, case900WithFloor.building.wall[1].propsBus_a.surfRad.Q_flow, case900WithoutFloor.building.wall[1].propsBus_a.surfRad.Q_flow. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The companion channel case900WithoutFloor.building.floor.propsBus_a.surfRad.Q_flow covers -911.138 to 2,266 W. At 1,770,000 s, the primary value is 3,277 and the companion is 2,266. Their signed difference is 1,012 W, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Compares a model with and without floor and its impact on beam radiation. The simulated case900WithFloor.building.floor.propsBus_a.surfRad.Q_flow channel runs from -932.466 to 3,277 W over 3,000,000 seconds.
Compares a model with and without floor and its impact on beam radiation. The simulated case900WithFloor.building.floor.propsBus_a.surfRad.Q_flow channel runs from -932.466 to 3,277 W over 3,000,000 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed case900WithFloor.building.floor.propsBus_a.surfRad.Q_flow samples by the trapezoidal rule gives 40.806 kWh over 3,000,000 seconds. For each pair, average the two powers in watts and multiply by the interval in seconds. Sum the watt-seconds and divide by 3,600,000. This value refers to the selected simulation connector and should be assigned to a physical load only after confirming the boundary and sign.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

case900WithFloor.building.floor.propsBus_a.surfRad.Q_flow (W)

case900WithoutFloor.building.floor.propsBus_a.surfRad.Q_flow (W)

0

33.56643

33.56643

600000

-37.72231

-160.4921

1200000

-459.3857

-470.0551

1620000

-932.4659

-820.459

1770000

3277.475

2265.925

1800000

-887.158

-911.1376

2400000

-429.8855

-394.8746

3000000

-163.3571

-172.6073

What to check on site

Check the time reference, location and receiving plane for each environmental input. Two measured series can differ because one records horizontal exposure and the other a tilted surface. A comparison needs the same averaging interval and geometric definition.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.