The recorded zone.TSensor temperature spans 16.653 °C to 33.906 °C in this simulation. That is a change of 17.253 K. The first saved maximum occurs at 10,940,000 s. The source trace and download retain absolute temperatures in kelvin.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named FacadeShadeExample. The source file places it under Buildings, Components. We used the 101 stored values for zone.TSensor over the interval 10,000,000 to 11,000,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name zoneSha (Case900 Template), zone (Case900 Template). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 10,880,000 s, zone.TSensor is 301.32 K and zoneSha.TSensor is 300.71 K. Subtracting the second value from the first gives 0.61002 K. This is their largest recorded absolute separation. A difference between an inlet and an outlet, or between a command and a response, need not be a measurement error.

Compares a building with shaded and unshaded facade. The simulated zone.TSensor channel runs from 289.803 to 307.056 source units over 1,000,000 seconds.
Compares a building with shaded and unshaded facade. The simulated zone.TSensor channel runs from 289.803 to 307.056 source units over 1,000,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 10,920,000 to 10,930,000 seconds. Subtracting 299.342 from 304.05 gives 4.707 source units. Its location brackets the change within one saved interval of 10,000 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

zone.TSensor (K)

zoneSha.TSensor (K)

1e+07

293.15

293.15

1.005e+07

289.8032

289.7886

1.02e+07

292.0583

291.7538

1.04e+07

291.0436

290.7334

1.06e+07

301.1588

300.6244

1.08e+07

298.0982

297.514

1.092e+07

299.3424

298.8092

1.093e+07

304.0496

303.5141

1.094e+07

307.0562

306.4958

1.1e+07

300.7224

300.2016

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Units in the source model

The component declarations identify the scale of the exported variables. In this run, zone.TSensor uses K and zoneSha.TSensor uses K. Keep the exact channel name and unit together when exporting data to a historian. Read the component definition.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.