The recorded VOut_flow.y channel spans 0.61 to 0.81 source units in this reference run. It starts at 0.61 and ends at 0.81. The first recorded maximum occurs at 1,800 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named Common_VOut_flow. The source file places it under Controls, OBC, ASHRAE, G36, AH Us, Multi Zone, variable air volume, Economizers, Subsequences, Limits. We used the 101 stored values for VOut_flow.y over the interval 0 to 1,800 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name VOutMinSet_flow (Constant), VOut_flow (Ramp), damLim (Common), fanStatus (Constant). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel damLim.damLimCon.y covers 0 to 0.01908 source units. At 1,800 s, the primary value is 0.81 and the companion is 0. Their signed difference is 0.81 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Common v out flow. The simulated VOut_flow.y channel runs from 0.61 to 0.81 source units over 1,800 seconds.
Common v out flow. The simulated VOut_flow.y channel runs from 0.61 to 0.81 source units over 1,800 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 18 to 36 seconds. Subtracting 0.612 from 0.614 gives 0.002 source units. Its location brackets the change within one saved interval of 18 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

VOut_flow.y (source units)

damLim.damLimCon.y (source units)

0

0.61

0.005

18

0.612

0.00564239

36

0.614

0.006269854

360

0.65

0.01499971

720

0.69

0.01899968

1080

0.73

0.01699965

1440

0.77

0.008999644

1800

0.81

0

What to check on site

Separate a calculated setpoint from the damper or fan command and from the measured service delivered. Trend the active operating mode, request, actual flow and zone condition on one clock. A sequence can change state correctly while the terminal fails to reach duty.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.