The senT1_1Ret.T trace covers 20 to 32.806 °C, a temperature span of 12.806 K. The first recorded maximum occurs at 2,000 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named CollectorDistributor. The source file places it under DHC, ETS. We used the 101 stored values for senT1_1Ret.T over the interval 0 to 5,000 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name sou1 (Flow Controlled m flow), sou2_1 (Flow Controlled m flow), bou1 (Boundary p T), m1 (Ramp). The source declares m_flow_nominal = 1. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel senT1_1Sup.T covers 293.15 to 313.15 K. At 100 s, the primary value is 298.369 and the companion is 313.068. Their signed difference is -14.699 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 50 to 100 seconds. Subtracting 294.27 from 298.369 gives 4.098 K. Its location brackets the change within one saved interval of 50 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | senT1_1Ret.T (K) | senT1_1Sup.T (K) |
|---|---|---|
0 | 293.15 | 293.15 |
50 | 294.2703 | 308.085 |
100 | 298.3686 | 313.068 |
1000 | 303.8387 | 313.15 |
2000 | 305.9558 | 313.15 |
3000 | 303.6638 | 313.15 |
4000 | 303.6075 | 313.15 |
5000 | 303.6057 | 313.15 |
What to check on site
Trace the transfer boundary between the central network and the local load. Identical terminal duty can coincide with different distribution losses and pump inputs. Use simultaneous primary and secondary measurements before allocating an energy difference to one side.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.
Cover photograph by Jakub Zerdzicki, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.