The solCol.vol[30].T trace covers 20 to 33.596 °C, a temperature span of 13.596 K. The first recorded maximum occurs at 38,016 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named EN12975NPanels. The source file places it under Fluid, Solar Collectors. We used the 101 stored values for solCol.vol[30].T over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name solCol (EN12975), weaDat (Reader TMY3), sou (Boundary p T), bou (Mass Flow Source T). The source declares nPanels = 10. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel solCol.heaLos.QLos_flow[30] starts at -5.225, ends at -9.284 and has a recorded range of -10.292 to -5.225 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.
![Collector according to EN 12975 with different settings for n panel. The simulated solCol.vol[30].T channel runs from 293.15 to 306.746 K over 86,400 seconds.](https://static.wixstatic.com/media/21e41b_6c7105444ea7415f9736b33e8d0eef40~mv2.png/v1/fill/w_616,h_345,al_c,q_85,enc_auto/21e41b_6c7105444ea7415f9736b33e8d0eef40~mv2.png)
Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0 to 864 seconds. Subtracting 293.15 from 302.512 gives 9.362 K. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | solCol.vol[30].T (K) | solCol.heaLos.QLos_flow[30] (source units) |
|---|---|---|
0 | 293.15 | -5.224683 |
864 | 302.5122 | -9.081545 |
17280 | 302.4459 | -10.09408 |
34560 | 305.8533 | -9.900119 |
38016 | 306.7464 | -10.01887 |
51840 | 306.3415 | -8.671379 |
69120 | 302.608 | -7.73315 |
86400 | 302.5006 | -9.283568 |
What to check on site
Check the time reference, location and receiving plane for each environmental input. Two measured series can differ because one records horizontal exposure and the other a tilted surface. A comparison needs the same averaging interval and geometric definition.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.