The solCol.sta_b.T trace covers 20 to 37.06 °C, a temperature span of 17.06 K. The first recorded maximum occurs at 38,880 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named EN12975_Series. The source file places it under Fluid, Solar Collectors. We used the 101 stored values for solCol.sta_b.T over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name solCol (Collector), solCol1 (Collector), solCol2 (Collector), weaDat (Reader TMY3). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The primary channel spends 97.0% of its saved checkpoints at or above 301.68 K, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 304.012 K. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Collector according to EN 12975 with different panels in series. The simulated solCol.sta_b.T channel runs from 293.15 to 310.21 K over 86,400 seconds.
Collector according to EN 12975 with different panels in series. The simulated solCol.sta_b.T channel runs from 293.15 to 310.21 K over 86,400 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 864 to 1,728 seconds. Subtracting 297.112 from 301.57 gives 4.458 K. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

solCol.sta_b.T (K)

0

293.15

864

297.112

1728

301.5704

17280

301.7767

34560

308.2274

38880

310.2098

51840

309.4102

69120

302.087

86400

301.879

What to check on site

Check the time reference, location and receiving plane for each environmental input. Two measured series can differ because one records horizontal exposure and the other a tilted surface. A comparison needs the same averaging interval and geometric definition.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.