The recorded solCol.sta_b.T temperature spans 20 °C to 43.273 °C in this simulation. That is a change of 23.273 K. The first saved maximum occurs at 38,880 s. The source trace and download retain absolute temperatures in kelvin.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named EN12975_Array. The source file places it under Fluid, Solar Collectors. We used the 101 stored values for solCol.sta_b.T over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name solCol (Collector), solCol1 (Collector), solCol2 (Collector), weaDat (Reader TMY3). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The primary channel spends 31.7% of its saved checkpoints at or above 304.787 K, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 304.817 K. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 864 to 1,728 seconds. Subtracting 294.081 from 296.984 gives 2.903 K. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | solCol.sta_b.T (K) |
|---|---|
0 | 293.15 |
864 | 294.0811 |
1728 | 296.9841 |
17280 | 300.5498 |
34560 | 311.8144 |
38880 | 316.4232 |
51840 | 315.0674 |
69120 | 301.118 |
86400 | 300.7311 |
What to check on site
Check the time reference, location and receiving plane for each environmental input. Two measured series can differ because one records horizontal exposure and the other a tilted surface. A comparison needs the same averaging interval and geometric definition.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.