The combinedHeatPower.fuelInput trace ranges from 0 W to 150,000 W across 101 saved checkpoints. It begins at 0 W and finishes at 150,000 W after 300 s of test time. The source identifies the channel scale as W. Its first saved maximum occurs at 210 s.
The system being tested
The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named CHPSystemNoControl. The source file places it under Fluid, Boiler CHP. We used the 101 stored values for combinedHeatPower.fuelInput over the interval 0 to 300 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name combinedHeatPower (CHP No Control), source (Mass Flow Source T), sink (Boundary p T), trapezoid (Trapezoid). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
At 210 s, combinedHeatPower.fuelInput is 150,000 W and combinedHeatPower.thermalPower is 82,000 W. Subtracting the second value from the first gives 68,000 W. This is their largest recorded absolute separation. A difference between an inlet and an outlet, or between a command and a response, need not be a measurement error.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 99 to 102 seconds. Subtracting 78,320 from 80,960 gives 2,640 source units. Its location brackets the change within one saved interval of 3 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | combinedHeatPower.fuelInput (W) | combinedHeatPower.thermalPower (W) |
|---|---|---|
0 | 0 | 0 |
60 | 44000 | 26000 |
99 | 78320 | 46280 |
102 | 80960 | 47840 |
120 | 96000 | 56600 |
180 | 136800 | 77800 |
210 | 150000 | 82000 |
240 | 150000 | 82000 |
300 | 150000 | 82000 |
What to check on site
Compare fuel or electrical input with useful heat at a declared delivery boundary. Include the warm-up interval and any period on standby. Separate a temperature setpoint from the measured outlet and keep auxiliary energy in a stated part of the balance.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Units in the source model
The component declarations identify the scale of the exported variables. In this run, combinedHeatPower.fuelInput uses W and combinedHeatPower.thermalPower uses W. Keep the exact channel name and unit together when exporting data to a historian. Read the component definition.