The heaPum.sta_a1.T trace covers 8.164 to 12 °C, a temperature span of 3.836 K. The first recorded maximum occurs at 0 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named EquationFitReversible_CoolingClosedLoop. The source file places it under Fluid, Heat Pumps. We used the 101 stored values for heaPum.sta_a1.T over the interval 0 to 2,500 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name heaPum (Equation Fit Reversible), reaToInt (Real To Integer), souPum (Mass Flow Source T), souVol (Fixed Boundary). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel heaPum.sta_b1.T covers 280.15 to 293.15 K. At 0 s, the primary value is 285.15 and the companion is 293.15. Their signed difference is -8 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Closed-loop of a reverse heat pump based on performance curves. The simulated heaPum.sta_a1.T channel runs from 281.314 to 285.15 K over 2,500 seconds.
Closed-loop of a reverse heat pump based on performance curves. The simulated heaPum.sta_a1.T channel runs from 281.314 to 285.15 K over 2,500 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 25 to 50 seconds. Subtracting 285.086 from 284.827 gives -0.259 K. Its location brackets the change within one saved interval of 25 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

heaPum.sta_a1.T (K)

heaPum.sta_b1.T (K)

0

285.15

293.15

25

285.0859

280.15

50

284.8268

280.15

500

282.8014

280.15

1000

281.9362

281.9362

1500

281.5357

280.15

2000

281.3742

281.3742

2500

281.3144

280.15

What to check on site

Read the evaporator, condenser and electrical channels at the same duty. The water or air temperatures entering the equipment constrain capacity and efficiency. A compressor command does not specify how much heat actually crosses the useful-load boundary.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.