The weaDat.weaBus.TDryBul trace covers -22.802 to 1.904 °C, a temperature span of 24.706 K. The first recorded maximum occurs at 163,296 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named TwoFloor_TwoZone. The source file places it under Scalable Benchmarks, Building variable air volume. We used the 101 stored values for weaDat.weaBus.TDryBul over the interval 0 to 604,800 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 3 recorded variables. Alongside the primary output there are weaDat.weaBus.TDryBul, weaDat.weaBus.HDirNor, weaDat.weaBus.HGloHor. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The companion channel weaDat.weaBus.HDirNor starts at 0, ends at 0 and has a recorded range of 0 to 902.003 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Closed-loop model with 2 zone in 2 floor. The simulated weaDat.weaBus.TDryBul channel runs from 250.348 to 275.054 K over 604,800 seconds.
Closed-loop model with 2 zone in 2 floor. The simulated weaDat.weaBus.TDryBul channel runs from 250.348 to 275.054 K over 604,800 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 356,832 to 362,880 seconds. Subtracting 265.825 from 261.564 gives -4.261 K. Its location brackets the change within one saved interval of 6,048 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

weaDat.weaBus.TDryBul (K)

weaDat.weaBus.HDirNor (source units)

0

260.95

0

120960

273.51

0.9586

163296

275.054

0

241920

270.35

0

356832

265.8252

0

362880

261.5641

0

483840

261.8193

96.41505

544320

250.3481

103.7648

604800

253.15

0

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.