Use simultaneous valid red and clear readings and assume 2,000 clear counts in each worked case. Dividing red by clear produces a dimensionless ratio. It is a relative signal descriptor, not a calibrated colour coordinate. With red-channel counts at 750, the worked result is 0.375 on the red-to-clear ratio at 2,000 clear counts scale.
The recorded quantity and the calculated result
Keep three columns in a commissioning export: the original red-channel counts, the configuration used in the conversion and the resulting red-to-clear ratio at 2,000 clear counts. Recompute the result for the lower, middle and upper worked points before interpreting a field difference. A change in range, units or representation can otherwise be mistaken for a change in the process.
Two points to check independently
Take the neighbouring worked points 500 and 750 on the input axis. The results are 0.25 and 0.375, giving a signed difference of 0.125. The table preserves the calculated values before display rounding. These are calculated examples under the stated assumptions. They are not readings from a ProSense installation.

Worked data
Red-channel counts | Red-to-clear ratio at 2,000 clear counts |
|---|---|
100 | 0.05 |
250 | 0.125 |
500 | 0.25 |
750 | 0.375 |
1000 | 0.5 |
1500 | 0.75 |
1900 | 0.95 |
Checking the ends of the working range
The final interval in this example runs from 750 to 1,900 on the red-channel counts axis. Its average change in red-to-clear ratio at 2,000 clear counts per input unit is 0.0005. This is a two-point slope for that interval. To check a spreadsheet or a gateway calculation, enter 1,900 in a separate test row and compare its result against 0.95 at the displayed precision.
Installation and interpretation
Check integration time, gain, saturation and the illumination spectrum. A near-zero clear reading makes a ratio unstable. Keep all four original channel readings so that a shift can be traced either to exposure or to the target colour.
For a repeatable verification, capture a small known case and a second case well away from it. Check whether the difference follows the response in the table, then restore the working configuration and repeat one reading. Store a separate status field for missing or invalid input. Substituting zero would make a dropped observation indistinguishable from a legitimate numerical zero.
Implementation and worked data
The source implementation is maintained in the .NET IoT device project. Download the worked numerical example.