The roo.T trace covers 19.933 to 20 °C, a temperature span of 0.06683 K. The first recorded maximum occurs at 36 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named ChimneyShaftNoVolume. The source file places it under Airflow, Multizone. We used the 101 stored values for roo.T over the interval 0 to 3,600 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name roo (Mixing Volume), oriChiTop (Orifice), boundary (Mass Flow Source T), bou0 (Boundary p T). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel con.y starts at 0, ends at 0.04443 and has a recorded range of -0.000188 to 0.334 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Chimney effect and a steady-state model of a shaft. The simulated roo.T channel runs from 293.083 to 293.15 K over 3,600 seconds.
Chimney effect and a steady-state model of a shaft. The simulated roo.T channel runs from 293.083 to 293.15 K over 3,600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 1,800 to 1,836 seconds. Subtracting 293.141 from 293.083 gives -0.05789 K. Its location brackets the change within one saved interval of 36 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

roo.T (K)

con.y (source units)

0

293.15

0

36

293.15

-0.0001880078

720

293.1411

0.04442644

1440

293.1411

0.04442649

1800

293.1411

0.04442649

1836

293.0832

0.3339267

1872

293.0832

0.3340359

2160

293.0832

0.3340305

2880

293.1411

0.0444265

3600

293.1411

0.04442649

What to check on site

Identify the connected zones, pressure references and flow direction. Changing a door, leakage path or boundary condition can redistribute the same total flow between branches. A differential pressure alone cannot establish the air quantity reaching a zone.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.