The recorded senTCDU_a.T temperature spans 20 °C to 43.029 °C in this simulation. That is a change of 23.029 K. The first saved maximum occurs at 252 s. The source trace and download retain absolute temperatures in kelvin.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named ChillerWSEDesignConditionsWater. The source file places it under Applications, Data Centers, Liquid Cooled. We used the 101 stored values for senTCDU_a.T over the interval 0 to 3,600 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 12 recorded variables. Alongside the primary output there are cdu.conVal.u_s, cdu.conVal.u_m, TSetRacIn.k, TSetRacOut.k, senTRac_b.T. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

At 72 s, senTCDU_a.T is 303.856 K and senTCDU_b.T is 322.995 K. Subtracting the second value from the first gives -19.14 K. This is their largest recorded absolute separation. A difference between an inlet and an outlet, or between a command and a response, need not be a measurement error.

Chiller waterside economiser design conditions water. The simulated senTCDU_a.T channel runs from 293.15 to 316.179 K over 3,600 seconds.
Chiller waterside economiser design conditions water. The simulated senTCDU_a.T channel runs from 293.15 to 316.179 K over 3,600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 36 seconds. Subtracting 293.15 from 299.422 gives 6.272 K. Its location brackets the change within one saved interval of 36 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

senTCDU_a.T (K)

senTCDU_b.T (K)

0

293.15

293.15

36

299.422

308.1294

252

316.1794

321.8243

720

315.2524

320.2547

1440

315.1507

320.1507

2160

315.1501

320.1501

2880

315.1501

320.1501

3600

315.15

320.15

What to check on site

Read the evaporator, condenser and electrical channels at the same duty. The water or air temperatures entering the equipment constrain capacity and efficiency. A compressor command does not specify how much heat actually crosses the useful-load boundary.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.