The recorded staSetCon.capReq.y channel spans 0 to 1,226,898 source units in this reference run. It starts at 0 and ends at 0. The first recorded maximum occurs at 5,880 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named SetpointController_WSE. The source file places it under Controls, OBC, ASHRAE, G36, Plants, Chillers, Staging, Set Points. We used the 101 stored values for staSetCon.capReq.y over the interval 0 to 14,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name staSetCon (Setpoint Controller), staSetCon1 (Setpoint Controller), TChiWatRet (Sin), chiWatFlow (Sin). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The two named channels have separate paths in the model. staSetCon.capReq.y begins at 0 and ends at 0. staSetCon.cap.yDes begins at 5e+05 and ends at 5e+05. The reference export supplies numerical samples but does not attach a physical unit to these fields. Use the linked model declarations to establish the quantity and units of each channel before calculating a difference or assigning it a physical meaning.

Chiller stage status setpoint signal generation for plants with waterside economiser. The simulated staSetCon.capReq.y channel runs from 0 to 1,226,898 source units over 14,000 seconds.
Chiller stage status setpoint signal generation for plants with waterside economiser. The simulated staSetCon.capReq.y channel runs from 0 to 1,226,898 source units over 14,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 3,920 to 4,060 seconds. Subtracting 733,308 from 1,032,673 gives 299,365 source units. Its location brackets the change within one saved interval of 140 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

staSetCon.capReq.y (source units)

staSetCon.cap.yDes (source units)

0

0

500000

2800

633980.2

500000

3920

733307.9

700000

4060

1032673

700000

5600

1195396

1200000

5880

1226898

1200000

8400

598771.1

1200000

11200

0

700000

14000

0

500000

What to check on site

Read the evaporator, condenser and electrical channels at the same duty. The water or air temperatures entering the equipment constrain capacity and efficiency. A compressor command does not specify how much heat actually crosses the useful-load boundary.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.