The TCWRet.T trace covers -0.03931 to 20 °C, a temperature span of 20.039 K. The first recorded maximum occurs at 0 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named IntegratedPrimarySecondaryEconomizer. The source file places it under Applications, Data Centers, Chiller Cooled. We used the 101 stored values for TCWRet.T over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name cooModCon (Cooling Mode), towTApp (Real Expression), yVal5 (Real Expression), cooLoaChi (Real Expression). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel TCWSup.T covers 273.111 to 293.15 K. At 84,672 s, the primary value is 278.874 and the companion is 277.073. Their signed difference is 1.801 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Chiller plant with integrated primary-secondary side economiser. The simulated TCWRet.T channel runs from 273.111 to 293.15 K over 86,400 seconds.
Chiller plant with integrated primary-secondary side economiser. The simulated TCWRet.T channel runs from 273.111 to 293.15 K over 86,400 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 864 seconds. Subtracting 293.15 from 273.111 gives -20.039 K. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

TCWRet.T (K)

TCWSup.T (K)

0

293.15

293.15

864

273.1107

273.1106

17280

279.7054

278.7964

34560

280.4762

278.8225

51840

282.0321

280.2586

69120

278.9051

277.1066

86400

278.9009

277.1022

What to check on site

Read the evaporator, condenser and electrical channels at the same duty. The water or air temperatures entering the equipment constrain capacity and efficiency. A compressor command does not specify how much heat actually crosses the useful-load boundary.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.