The recorded heaCon.yVal channel spans -0.2 to 0.4 source units in this reference run. It starts at 0.1 and ends at 0.1. The first recorded maximum occurs at 300 seconds and the first minimum at 900 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named Reheat. The source file places it under Applications, Data Centers, Chiller Cooled, Controls. We used the 101 stored values for heaCon.yVal over the interval 0 to 1,200 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name heaCon (Reheat), sig1 (Sine), sig2 (Sine), set1 (Constant). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel heaCon.y starts at 0, ends at 0 and has a recorded range of 0 to 1 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0 to 12 seconds. Subtracting 0.1 from 0.1188 gives 0.01884 source units. Its location brackets the change within one saved interval of 12 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | heaCon.yVal (source units) | heaCon.y (source units) |
|---|---|---|
0 | 0.1 | 0 |
12 | 0.1188372 | 0 |
240 | 0.385317 | 0 |
300 | 0.4 | 0 |
480 | 0.2763356 | 0 |
720 | -0.07633558 | 1 |
900 | -0.2 | 1 |
960 | -0.185317 | 1 |
1200 | 0.1 | 0 |
What to check on site
Read the evaporator, condenser and electrical channels at the same duty. The water or air temperatures entering the equipment constrain capacity and efficiency. A compressor command does not specify how much heat actually crosses the useful-load boundary.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.