The chiWatPumSpe.y[1] trace ranges from 0 to 0.61209 across 101 saved checkpoints. It begins at 0 and finishes at 0.61209 after 1,200 s of test time. The source identifies the channel scale as dimensionless. Its first saved maximum occurs at 1,200 s.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named ChilledWaterPumpSpeed. The source file places it under DHC, Plants, Cooling, Controls. We used the 101 stored values for chiWatPumSpe.y[1] over the interval 0 to 1,200 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name chiWatPumSpe (Chilled Water Pump Speed), mFloTot (Pulse), dpMea (Pulse), on (Constant). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 864 s, chiWatPumSpe.y[1] reads 0.48144 and chiWatPumSpe.dpMea reads 55,120 Pa. Across the run, the second channel ranges from 55,120 Pa to 82,680 Pa. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Chilled water pump speed. The simulated chiWatPumSpe.y[1] channel runs from 0 to 0.6121 source units over 1,200 seconds.
Chilled water pump speed. The simulated chiWatPumSpe.y[1] channel runs from 0 to 0.6121 source units over 1,200 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 852 to 864 seconds. Subtracting 0 from 0.4814 gives 0.4814 source units. Its location brackets the change within one saved interval of 12 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

chiWatPumSpe.y[1] (dimensionless)

chiWatPumSpe.dpMea (Pa)

0

0

82680

240

0

55120

480

0.06470686

82680

720

0.4934114

55120

852

0

55120

864

0.4814417

55120

960

0.001441699

82680

1200

0.6120926

55120

What to check on site

Mark the measurement points on a hydraulic schematic and identify whether the controller holds flow or differential pressure. Record pump command and delivered duty together. A site comparison needs the same branch state, including bypasses and closed valves.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Units in the source model

The component declarations identify the scale of the exported variables. In this run, chiWatPumSpe.y[1] uses dimensionless and chiWatPumSpe.dpMea uses Pa. Keep the exact channel name and unit together when exporting data to a historian. Read the component definition.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.