The recorded outerWall.layMul.monLay[2].port_a.T temperature spans 2.4795 °C to 20 °C in this simulation. That is a change of 17.521 K. The first saved maximum occurs at 0 s. The source trace and download retain absolute temperatures in kelvin.
The system being tested
The KU Leuven IDEAS project publishes the IDEAS test named CavityWalls. The source file places it under Buildings, Components. We used the 101 stored values for outerWall.layMul.monLay[2].port_a.T over the interval 0 to 1,000,000 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name outerWall (Outer Wall), win (Window). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
At 270,000 s, outerWall.layMul.monLay[2].port_a.T is 277.671 K and outerWall.layMul.monLay[2].port_b.T is 276.845 K. Subtracting the second value from the first gives 0.82544 K. This is their largest recorded absolute separation. A difference between an inlet and an outlet, or between a command and a response, need not be a measurement error.
![Check of air cavity models in glazing and partially filled cavity walls. The simulated outerWall.layMul.monLay[2].port_a.T channel runs from 275.629 to 293.15 K over 1,000,000 seconds.](https://static.wixstatic.com/media/21e41b_08320509413447cd96efa0d309ddcda3~mv2.png/v1/fill/w_616,h_345,al_c,q_85,enc_auto/21e41b_08320509413447cd96efa0d309ddcda3~mv2.png)
Reproduce the calculation
The largest absolute change between consecutive stored points appears from 730,000 to 740,000 seconds. Subtracting 279.246 from 286.429 gives 7.183 K. Its location brackets the change within one saved interval of 10,000 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | outerWall.layMul.monLay[2].port_a.T (K) | outerWall.layMul.monLay[2].port_b.T (K) |
|---|---|---|
0 | 293.15 | 293.15 |
200000 | 277.9363 | 277.1366 |
400000 | 282.2845 | 282.0525 |
600000 | 280.6201 | 280.4668 |
730000 | 279.246 | 279.2021 |
740000 | 286.429 | 286.9869 |
800000 | 276.4531 | 275.7778 |
890000 | 275.6295 | 275.1022 |
1000000 | 280.5049 | 280.3433 |
What to check on site
Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.

![Check of air cavity models in glazing and partially filled cavity walls. outerWall.layMul.monLay[2].port_a.T (K) ranges from 275.63 to 293.15 across the recorded simulation time (s) interval of 0 to 1e+06. Bands show the minimum and maximum per group of samples. Crossbars mark the median.](/story-art/269cffa8aac7659cc.webp)