The lowest observed group mean is 526.8 for group Id group 5. The highest is 562.6 for group 3, a difference of 35.8 on the source response scale. Across all 25 numeric records the response median is 538.
What was measured
The NATR341 data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as breaking Strength. It preserves the source scale and its sign. The file contains 2 numeric fields per accepted row.
Spread across the original readings
The two endpoint groups have 5 and 5 observations. Their medians are 528 and 554, respectively. The figure groups the original entries by the recorded group Id value. Where there are more than eight distinct settings, it groups them at empirical quartiles and labels each band with its observed endpoints.

One row you can check
To check a real observation, take numeric row 14 after the header. Its response is 538. The overall arithmetic mean is 541.84, so this observation is -3.84 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 27, calculated by subtracting 528 from 555.
The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.
Worked data
group Id group | Observations | Mean response | Median response | Minimum response | Maximum response |
|---|---|---|---|---|---|
1 | 5 | 534 | 538 | 510 | 560 |
2 | 5 | 536.4 | 534 | 508 | 574 |
3 | 5 | 562.6 | 554 | 538 | 598 |
4 | 5 | 549.4 | 550 | 535 | 567 |
5 | 5 | 526.8 | 528 | 492 | 572 |
Implications for an industrial comparison
Compare the specimen geometry, preparation, loading direction, conditioning and endpoint before using this distribution in a materials decision. Failure observations from a controlled test do not directly provide a field failure probability. A comparison with current production also needs the number of specimens withdrawn before the stated endpoint.
Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.
Source file and worked data
The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.