The recorded winNor.shaType.HDirTil channel spans 0 to 213.211 source units in this reference run. It starts at 0 and ends at 0.08479. The first recorded maximum occurs at 2,640,000 seconds and the first minimum at 2,000,000 seconds.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named CeilingOrientationConsistency. The source file places it under Buildings, Components, Validations. We used the 101 stored values for winNor.shaType.HDirTil over the interval 2,000,000 to 3,000,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name winSou (Window), winEas (Window), winNor (Window). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel winNor.shaType.HSkyDifTil covers 0 to 126.175 source units. At 2,640,000 s, the primary value is 213.211 and the companion is 97.667. Their signed difference is 115.545 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Ceiling orientation consistency. The simulated winNor.shaType.HDirTil channel runs from 0 to 213.211 source units over 1,000,000 seconds.
Ceiling orientation consistency. The simulated winNor.shaType.HDirTil channel runs from 0 to 213.211 source units over 1,000,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 2,450,000 to 2,460,000 seconds. Subtracting 0.6787 from 188.937 gives 188.259 source units. Its location brackets the change within one saved interval of 10,000 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

winNor.shaType.HDirTil (source units)

winNor.shaType.HSkyDifTil (source units)

2000000

0

0

2200000

2.161661

58.23196

2400000

0

0

2450000

0.6787093

28.83789

2460000

188.9374

88.67735

2600000

0

0

2640000

213.2113

97.66666

2800000

1.244948

12.61245

3000000

0.0847881

4.662888

What to check on site

Check the time reference, location and receiving plane for each environmental input. Two measured series can differ because one records horizontal exposure and the other a tilted surface. A comparison needs the same averaging interval and geometric definition.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model