A serial update of every register shifts eight bits per device before the output latch is updated. The worked count is independent of the logic levels being sent. The latch event is additional to the shift-clock count plotted here. With eight-bit output devices at 4, the worked result is 32 on the shift clock edges per full chain update scale.
The recorded quantity and the calculated result
Keep three columns in a commissioning export: the original eight-bit output devices, the configuration used in the conversion and the resulting shift clock edges per full chain update. Recompute the result for the lower, middle and upper worked points before interpreting a field difference. A change in range, units or representation can otherwise be mistaken for a change in the process.
Two points to check independently
Take the neighbouring worked points 3 and 4 on the input axis. The results are 24 and 32, giving a signed difference of 8. The table preserves the calculated values before display rounding. These are calculated examples under the stated assumptions. They are not readings from a ProSense installation.

Worked data
Eight-bit output devices | Shift clock edges per full chain update |
|---|---|
1 | 8 |
2 | 16 |
3 | 24 |
4 | 32 |
6 | 48 |
8 | 64 |
16 | 128 |
Checking the ends of the working range
The final interval in this example runs from 4 to 16 on the eight-bit output devices axis. Its average change in shift clock edges per full chain update per input unit is 8. This is a two-point slope for that interval. To check a spreadsheet or a gateway calculation, enter 16 in a separate test row and compare its result against 128 at the displayed precision.
Installation and interpretation
Separate serial shifting from the visible output transition. A field signal sampled during a transfer can give a different impression depending on whether the design observes shift data or the latched outputs. Record the update boundary when multiple indicators should change together.
For a repeatable verification, capture a small known case and a second case well away from it. Check whether the difference follows the response in the table, then restore the working configuration and repeat one reading. Store a separate status field for missing or invalid input. Substituting zero would make a dropped observation indistinguishable from a legitimate numerical zero.
Implementation and worked data
The source implementation is maintained in the .NET IoT device project. Download the worked numerical example.