The bui.ets.theMixVal.senTHot.T trace covers 15.162 to 53.493 °C, a temperature span of 38.331 K. The first recorded maximum occurs at 43,200 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named BuildingTimeSeriesWithETSDHWTank. The source file places it under DHC, Loads, Combined. We used the 101 stored values for bui.ets.theMixVal.senTHot.T over the interval 0 to 864,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name supAmbWat (Boundary p T), sinAmbWat (Boundary p T), senMasFlo (Mass Flow Rate), TDisSup (Constant). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel bui.ets.proHeaWat.senTDisSup.T covers 288.15 to 293.15 K. At 43,200 s, the primary value is 326.643 and the companion is 288.153. Their signed difference is 38.489 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Building time series with etsdhw tank. The simulated bui.ets.theMixVal.senTHot.T channel runs from 288.312 to 326.643 K over 864,000 seconds.
Building time series with etsdhw tank. The simulated bui.ets.theMixVal.senTHot.T channel runs from 288.312 to 326.643 K over 864,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 665,280 to 673,920 seconds. Subtracting 325.597 from 288.312 gives -37.285 K. Its location brackets the change within one saved interval of 8,640 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

bui.ets.theMixVal.senTHot.T (K)

bui.ets.proHeaWat.senTDisSup.T (K)

0

288.3119

293.15

43200

326.6427

288.1535

172800

288.3119

288.15

345600

288.3119

288.15

518400

288.3119

288.15

665280

325.5968

288.15

673920

288.3119

288.15

691200

288.3119

288.15

864000

288.3119

288.15

What to check on site

Read the evaporator, condenser and electrical channels at the same duty. The water or air temperatures entering the equipment constrain capacity and efficiency. A compressor command does not specify how much heat actually crosses the useful-load boundary.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.