The hea.sta_a.T trace covers 7.5 to 19.435 °C, a temperature span of 11.935 K. The first recorded maximum occurs at 2,678,400 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named RectangularBorefield. The source file places it under Fluid, Geothermal, Borefields. We used the 101 stored values for hea.sta_a.T over the interval 0 to 2,678,400 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name borFie (One U Tube), bou (Boundary p T), hea (Heater T), TSou (Constant). The source declares tLoaAgg = 300, TGro = 283.15, v_nominal = 1, dpHex_nominal = 10000. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel borFie.groTemRes.delTBor starts at 0, ends at 5.164 and has a recorded range of 0 to 5.164 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0 to 26,784 seconds. Subtracting 280.65 from 292.216 gives 11.566 K. Its location brackets the change within one saved interval of 26,784 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | hea.sta_a.T (K) | borFie.groTemRes.delTBor (source units) |
|---|---|---|
0 | 280.65 | 0 |
26784 | 292.216 | 1.582107 |
535680 | 292.4969 | 4.086716 |
1071360 | 292.5339 | 4.534667 |
1607040 | 292.5549 | 4.790603 |
2142720 | 292.5713 | 4.991367 |
2678400 | 292.5854 | 5.164265 |
What to check on site
The thermal history of a borefield matters across repeated loads. Distinguish a fluid outlet reading from pipe wall, grout and far-field temperatures. Record the duration and sign of each heat pulse before comparing an installation with a reference case.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.
Cover photograph by Jakub Zerdzicki, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.