The recorded bli.TIn temperature spans 4.8607 °C to 34.849 °C in this simulation. That is a change of 29.988 K. The first saved maximum occurs at 252 s. The source trace and download retain absolute temperatures in kelvin.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named Haldi2008BlindsTIn. The source file places it under Occupants, Office, Blinds. We used the 101 stored values for bli.TIn over the interval 0 to 3,600 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name occ (Boolean Step), TIn (Sine), bli (Haldi2008 Blinds T In). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 2,016 s, bli.TIn reads 294.505 K and bli.occ reads 1. Across the run, the second channel ranges from 0 to 1. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Blinds blind behaviors. The simulated bli.TIn channel runs from 278.011 to 307.999 K over 3,600 seconds.
Blinds blind behaviors. The simulated bli.TIn channel runs from 278.011 to 307.999 K over 3,600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 1,980 to 2,016 seconds. Subtracting 291.12 from 294.505 gives 3.385 K. Its location brackets the change within one saved interval of 36 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

bli.TIn (K)

bli.occ (logical state)

0

293

0

252

307.9988

0

720

278.2657

0

756

278.0107

0

1440

298.5219

0

1980

291.12

1

2016

294.5054

1

2160

305.6649

1

2880

282.7318

1

3600

284.1832

1

What to check on site

Identify the stored quantity and the boundary through which energy or mass enters. A layer temperature, outlet temperature and volume mean describe different states. Preserve initial inventory and the sequence of charge or discharge when repeating the case.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Units in the source model

The component declarations identify the scale of the exported variables. In this run, bli.occ uses logical state. Keep the exact channel name and unit together when exporting data to a historian. Read the component definition.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.