The recorded dp channel spans -8.163 to 8.163 Pa in this reference run. It starts at -8.163 and ends at 8.163. The first recorded maximum occurs at 2 seconds and the first minimum at -2 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named BasicFlowFunction_m_flow_DerivativeCheck2. The source file places it under Fluid, Flow Models. We used the 101 stored values for dp over the interval -2 to 2 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name cheEqu1 (Check Equality), cheEqu2 (Check Equality), dp (Pressure Difference), dp_comp (Pressure Difference). The source declares k = 0.35, m_flow_turbulent = 0.36. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel dp_comp starts at -8.163, ends at 8.163 and has a recorded range of -8.163 to 8.163 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Basic flow function mass flow derivative check2. The simulated dp channel runs from -8.163 to 8.163 Pa over 4 seconds.
Basic flow function mass flow derivative check2. The simulated dp channel runs from -8.163 to 8.163 Pa over 4 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from -2 to -1.96 seconds. Subtracting -8.163 from -7.231 gives 0.9319 Pa. Its location brackets the change within one saved interval of 0.04 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

dp (Pa)

dp_comp (source units)

-2

-8.163265

-8.163265

-1.96

-7.231365

-7.231365

-1.2

-0.3991468

-0.3991468

-0.4

-0.008825033

-0.008825519

0.4

0.008825033

0.008824319

1.2

0.3991468

0.3991462

2

8.163265

8.163264

What to check on site

Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.