The lowest observed group mean is 4,131 for contamination group 160. The highest is 17,410 for group 30, a difference of 13,279 on the source response scale. Across all 35 numeric records the response median is 1,152.
What was measured
The ROSSITE2 data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as hours to failure. It preserves the source scale and its sign. The file contains 4 numeric fields per accepted row.
Spread across the original readings
The two endpoint groups have 18 and 17 observations. Their medians are 363.55 and 16,870, respectively. The figure groups the original entries by the recorded contamination value. Where there are more than eight distinct settings, it groups them at empirical quartiles and labels each band with its observed endpoints.

One row you can check
To check a real observation, take numeric row 6 after the header. Its response is 1,152. The overall arithmetic mean is 10,580, so this observation is -9,428 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 21,373, calculated by subtracting 174.275 from 21,548.
The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.
Worked data
contamination group | Observations | Mean response | Median response | Minimum response | Maximum response |
|---|---|---|---|---|---|
30 | 17 | 17409.51 | 16870 | 148.86 | 37000 |
160 | 18 | 4130.72 | 363.55 | 66.78 | 37000 |
Implications for an industrial comparison
Compare the specimen geometry, preparation, loading direction, conditioning and endpoint before using this distribution in a materials decision. Failure observations from a controlled test do not directly provide a field failure probability. A comparison with current production also needs the number of specimens withdrawn before the stated endpoint.
Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.
Source file and worked data
The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.