The noSenZon.TDis trace covers 15 to 25 °C, a temperature span of 10 K. The first recorded maximum occurs at 5,400 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named Setpoints. The source file places it under Controls, OBC, ASHRAE, G36, Ventilation Zones, ASHRAE62 1. We used the 101 stored values for noSenZon.TDis over the interval 0 to 7,200 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name noSenZon (Setpoints), winSenZon (Setpoints), occSenZon (Setpoints), co2SenZon (Setpoints). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel noSenZon.TZon covers 280.15 to 296.15 K. At 5,400 s, the primary value is 298.15 and the companion is 280.15. Their signed difference is 18 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Ashrae62 1 setpoints. The simulated noSenZon.TDis channel runs from 288.15 to 298.15 K over 7,200 seconds.
Ashrae62 1 setpoints. The simulated noSenZon.TDis channel runs from 288.15 to 298.15 K over 7,200 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 3,600 to 3,672 seconds. Subtracting 293.15 from 293.464 gives 0.314 K. Its location brackets the change within one saved interval of 72 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

noSenZon.TDis (K)

noSenZon.TZon (K)

0

293.15

288.15

1440

288.3947

295.7585

1800

288.15

296.15

2880

290.2111

292.8523

3600

293.15

288.15

3672

293.464

287.6477

4320

296.0889

283.4477

5400

298.15

280.15

5760

297.9053

280.5415

7200

293.15

288.15

What to check on site

Separate a calculated setpoint from the damper or fan command and from the measured service delivered. Trend the active operating mode, request, actual flow and zone condition on one clock. A sequence can change state correctly while the terminal fails to reach duty.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.