The recorded hvac.damOut.y channel spans 0 to 0.5282 source units in this reference run. It starts at 0 and ends at 0. The first recorded maximum occurs at 712,800 seconds and the first minimum at 432,000 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named ASHRAE2006Winter_Autosizing. The source file places it under Thermal Zones, Energy Plus 24 2 0, Small Office. We used the 101 stored values for hvac.damOut.y over the interval 432,000 to 864,000 seconds. This is a simulated test with specified inputs and boundaries.

The source declares TCooAirSup_nominal = 12+273.15, XCooAirSup_nominal = 0.0085/(1+0.0085), THeaAirDis_nominal = 40+273.15. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel hvac.fanSup.y covers 0 to 1 source units. At 453,600 s, the primary value is 0 and the companion is 1. Their signed difference is -1 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Ashrae2006 winter autosizing. The simulated hvac.damOut.y channel runs from 0 to 0.5282 source units over 432,000 seconds.
Ashrae2006 winter autosizing. The simulated hvac.damOut.y channel runs from 0 to 0.5282 source units over 432,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 708,480 to 712,800 seconds. Subtracting 0 from 0.5282 gives 0.5282 source units. Its location brackets the change within one saved interval of 4,320 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

hvac.damOut.y (source units)

hvac.fanSup.y (source units)

432000

0

0

518400

0

0

604800

0

0

691200

0

0

708480

0

0

712800

0.5282131

1

777600

0

0

864000

0

0

What to check on site

Identify the stored quantity and the boundary through which energy or mass enters. A layer temperature, outlet temperature and volume mean describe different states. Preserve initial inventory and the sequence of charge or discharge when repeating the case.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.