The recorded aquWel.TAquCol[150] channel spans 307.15 to 384.565 source units in this reference run. It starts at 307.15 and ends at 320.842. The first recorded maximum occurs at 10,091,520 seconds and the first minimum at 0 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named SimulationTest. The source file places it under Fluid, Geothermal, Aquifer. We used the 101 stored values for aquWel.TAquCol[150] over the interval 0 to 31,536,000 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name aquWel (Multi Well), bou (Boundary p T). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The primary channel spends 50.5% of its saved checkpoints at or above 345.858 source units, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 350.243 source units. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.
![Aquifer thermal energy storage in comparison with other geothermal simulators. The simulated aquWel.TAquCol[150] channel runs from 307.15 to 384.565 source units over 31,536,000 seconds.](https://static.wixstatic.com/media/21e41b_29f3e9c7db9c45868f40e361d581aa15~mv2.png/v1/fill/w_616,h_345,al_c,q_85,enc_auto/21e41b_29f3e9c7db9c45868f40e361d581aa15~mv2.png)
Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0 to 315,360 seconds. Subtracting 307.15 from 330.018 gives 22.868 source units. Its location brackets the change within one saved interval of 315,360 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | aquWel.TAquCol[150] (source units) |
|---|---|
0 | 307.15 |
315360 | 330.018 |
6307200 | 381.5008 |
1.009152e+07 | 384.5651 |
1.26144e+07 | 364.776 |
1.89216e+07 | 337.2624 |
2.52288e+07 | 324.7143 |
3.1536e+07 | 320.8421 |
What to check on site
The thermal history of a borefield matters across repeated loads. Distinguish a fluid outlet reading from pipe wall, grout and far-field temperatures. Record the duration and sign of each heat pulse before comparing an installation with a reference case.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.

![Aquifer thermal energy storage in comparison with other geothermal simulators. aquWel.TAquCol[150] (source units) ranges from 307.15 to 384.57 across the recorded simulation time (s) interval of 0 to 3.1536e+07. Bands show the minimum and maximum per group of samples. Crossbars mark the median.](/story-art/762d0081a54532254.webp)