The recorded d channel spans 997.35 to 1,077 source units in this reference run. It starts at 997.35 and ends at 1,077. The first recorded maximum occurs at 1 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named EthyleneGlycolWater. The source file places it under Media, Antifreeze, Functions. We used the 101 stored values for d over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name phi (Real), X_a_phi (Mass Fraction), X_a (Mass Fraction), d (Density). The source declares T = 293.15. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel Pr covers 7.187 to 42.937 source units. At 0.96 s, the primary value is 1,074 and the companion is 40.003. Their signed difference is 1,034 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Antifreeze mixture. The simulated d channel runs from 997.35 to 1,077 source units over 1 seconds.
Antifreeze mixture. The simulated d channel runs from 997.35 to 1,077 source units over 1 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0.47 to 0.48 seconds. Subtracting 1,036 from 1,036 gives 0.8403 source units. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

d (source units)

Pr (source units)

0

997.3503

7.186676

0.2

1013.242

10.00167

0.4

1029.652

14.45747

0.47

1035.525

16.41599

0.48

1036.365

16.71477

0.6

1046.395

20.73094

0.8

1062.392

29.80924

1

1077.139

42.93712

What to check on site

Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.