The archived response ranges from 24.21 to 75.7. The median is 41.295 and the central half of the measurements extends from 36.498 to 48.407. Those figures use all 60 numeric observations in this source series and retain its original measurement scale.

What was measured

The CASTILL2 data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as maximum yearly river flow discharge. It preserves the source scale and its sign. The file contains 1 numeric field per accepted row.

Spread across the original readings

The tenth percentile is 33.015 and the ninetieth is 53.047. They provide a narrower description of the typical spread than the minimum and maximum. The largest and smallest observed records are separated by 51.49. This is the range of this sample, rather than a guaranteed operating envelope.

Annual peak river discharge. The 25th, 50th and 75th percentiles of the measurements are 36.498, 41.295 and 48.407.
Annual peak river discharge. The 25th, 50th and 75th percentiles of the measurements are 36.498, 41.295 and 48.407. Figure by Industry Applied.

One row you can check

To check a real observation, take numeric row 31 after the header. Its response is 41.54. The overall arithmetic mean is 42.885, so this observation is -1.345 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 11.91, calculated by subtracting 36.498 from 48.407.

The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.

Worked data

Percentile

Observed response (source scale)

Number of numeric rows

0

24.21

60

10

33.015

60

25

36.4975

60

50

41.295

60

75

48.4075

60

90

53.047

60

100

75.7

60

Implications for an industrial comparison

Keep the measurement location, observation interval and averaging rule beside the figure. An extreme in a short record cannot supply a design return period. When comparing installations or environmental records, check whether both instruments observed the same temporal and spatial scale.

Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.

Source file and worked data

The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.