The archived response ranges from 22.64 to 98.16. The median is 29.83 and the central half of the measurements extends from 26.738 to 37.875. Those figures use all 50 numeric observations in this source series and retain its original measurement scale.
What was measured
The CASTILL1 data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as maximum yearly wind speed (mph). It preserves the source scale and its sign. The file contains 1 numeric field per accepted row.
Spread across the original readings
The tenth percentile is 24.22 and the ninetieth is 44.673. They provide a narrower description of the typical spread than the minimum and maximum. The largest and smallest observed records are separated by 75.52. This is the range of this sample, rather than a guaranteed operating envelope.

One row you can check
To check a real observation, take numeric row 25 after the header. Its response is 29.48. The overall arithmetic mean is 34.02, so this observation is -4.54 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 11.137, calculated by subtracting 26.738 from 37.875.
The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.
Worked data
Percentile | Observed response (source scale) | Number of numeric rows |
|---|---|---|
0 | 22.64 | 50 |
10 | 24.22 | 50 |
25 | 26.7375 | 50 |
50 | 29.83 | 50 |
75 | 37.875 | 50 |
90 | 44.673 | 50 |
100 | 98.16 | 50 |
Implications for an industrial comparison
Keep the measurement location, observation interval and averaging rule beside the figure. An extreme in a short record cannot supply a design return period. When comparing installations or environmental records, check whether both instruments observed the same temporal and spatial scale.
Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.
Source file and worked data
The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.
Cover photograph by Mark Stebnicki, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.