The recorded case900_comfort.building.gF.comfort.PMV channel spans -3.225 to -1.011 source units in this reference run. It starts at -1.947 and ends at -2.936. The first recorded maximum occurs at 140,000 seconds and the first minimum at 880,000 seconds.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named ComfortExample. The source file places it under Buildings. We used the 101 stored values for case900_comfort.building.gF.comfort.PMV over the interval 0 to 1,000,000 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 2 recorded variables. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The companion channel case900_comfort.building.gF.comfort.PPD covers 0.2659 to 0.9974 source units. At 880,000 s, the primary value is -3.225 and the companion is 0.9974. Their signed difference is -4.223 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

And without occupant. The simulated case900_comfort.building.gF.comfort.PMV channel runs from -3.225 to -1.011 source units over 1,000,000 seconds.
And without occupant. The simulated case900_comfort.building.gF.comfort.PMV channel runs from -3.225 to -1.011 source units over 1,000,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 130,000 to 140,000 seconds. Subtracting -2.119 from -1.011 gives 1.108 source units. Its location brackets the change within one saved interval of 10,000 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

case900_comfort.building.gF.comfort.PMV (source units)

case900_comfort.building.gF.comfort.PPD (source units)

0

-1.947225

0.7432257

130000

-2.119222

0.8184463

140000

-1.01111

0.2658979

200000

-2.951399

0.9888189

400000

-2.753802

0.9735362

600000

-2.92958

0.9876137

800000

-3.042938

0.9928719

880000

-3.225215

0.9973835

1000000

-2.936173

0.9879887

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.